226 ETMS: ENVIRONMENTAL TELE-MONITORING SYSTEM-WCL:Tawa 2 Mine - Pathakhera Area Outstation Location Sensor Location CH4 (%) CO (ppm) O2 (%) Temperature (°C) AV(m/sec) OS: 1 – 0D/1L SS-1, 0L/4R – IV SEAM 0.00% 0 ppm 20.70% 25.0°C 3.81 m/s OS: 2 – 0D/20L SS-2, 23L/3R – IV SEAM 0.00% 0 ppm 0.00% 0.0°C 0.00 m/s OS: 3 – 3R/24L SS-3, 24L/7R – IV SEAM 0.00% 1 ppm 20.60% 26.7°C 0.67 m/s OS: 4 – 26L/6D SS-4, 30L/3R – IV SEAM 0.01% 0 ppm 20.80% 25.5°C 0.01 m/s OS: 5 – 16D/26L SS-5, 26L/17R – II SEAM 0.00% 0 ppm 20.90% 27.9°C 0.68 m/s OS: 6 –32D/32L SS-6, 32L/33R – IV SEAM 0.01% 0 ppm 19.40% 26.8°C - OS: 7 –36L/33R SS-7, 40L/33R – IV SEAM 0.00% 7 ppm 20.10% 27.0°C 2.69 m/s Table 1 1.8) IIoT based remote pump monitoring System: Water pumping is a critical activity in an opencast mine. ICCC also remotely monitor water pumps installed in opencast mines. The system has a provision for monitoring of various pump parameters such as flow, vibration patterns, energy consumption, efficiency, scope for Customization for AI based decision making as explained with a schematic diagram below. And even remote switch on/off facility. The system helps in energy saving, cost cutting on spares and provides a predictive system for breakdown/maintenance avoiding manual operations in unsafe watery conditions. A schematic
RkJQdWJsaXNoZXIy MTM0Mzk2