#1 button filter plates use a closed filtrate discharge system, in which filtrate leaves the system via a piping system. It is considered closed because the filtrate is not readily visible as it leaves the system. Because of this design, it’s difficult to visually identify which specific plate has a failed cloth. When there is a cloth failure, or a cloth is suspected to be failing the operator must manually inspect all #1 button plates to find the source of the issue. The #3 button plates discharge filtrate from the bottom of each plate to the drip trays below. As the filtrate leaves out the bottom of the filter plate it is easily visible, making it easy for operators to visually spot dirty filtrate. This allows them to quickly identify and address the specific plate or cloth that has failed. 2.1.2 Closed discharge filter #1 and #3 button filter plates use a closed filtrate discharge system, in which filtrate leaves the system via a piping system. The #1 button plates will discharge filtrate out either the left or right side of the filter plate and te #3 button plate will discharge out the opposite side as the #1 button plates. It is considered closed because the filtrate is not readily visible as it leaves the filter. Most filter presses operate in this configuration. When turbidity is detected, the operator must inspect all plates and cloth to determine which chamber was affected. 2.2 Failed media detection techniques 2.2.1 Visual and physical inspections A physical inspection of a torn filter cloth usually includes visually examining each filter cloth and surrounding areas for tears, holes, or signs of damage. This includes checking for any visible inconsistencies in the cloth's surface and edges. A visual check should be done during a regular maintenance routine. A torn filter cloth is often indicated by a distinct whistling or blowing sound during the air blow. This audible anomaly enables the operator to identify the location of the damaged cloth. 2.2.2 Filtrate clarity and composition using a bulk turbidity sensor Torn filter media can be detected by observing bulk turbidity in the filtrate. These bulk turbidity sensors are usually installed at one end of the filter press. A sudden or gradual cloudiness, or increased turbidity, in the filtrate indicates that particles are passing through the cloth due to tears or other damage. This is because a torn cloth allows unfiltered solids to enter the filtrate stream, increasing its turbidity. 2.2.3 Operational and Peformance Metrics The inability of the filter press to achieve or maintain the required operating pressure during the filtration phase is typically indicative of a significant failure within the filter media. This condition often results from extensive tears or multiple breaches distributed across the filter cloths within the plate stack. Such failures compromise the integrity of the seal between filter plates, leading to what is commonly referred to as a “blowout,” wherein the filter cloth can no
RkJQdWJsaXNoZXIy MTM0Mzk2