Figure 7 – Intelliplate diagram installed on a filter plate 4.2 Processing Turbidity Signal A supplied software that can be installed either on a separate HMI, the local PLC for the filter press, or a DCS. This software aggregates data from the receiver unit and displays the realtime status of each connected turbidity sensor. When turbidity is detected by any sensor, the system triggers an alarm to notify the operator of the event.